DXL360/S/C V2 Digital Protractor
User Guide
Features:
1) DXL360S/C: High accuracy ±0.05°, high resolution 0.01°
DXL360: ±0.1°, resolution 0.02°, detail check specification
2) Dual and Single axis with user friendly LCD display angle
3) Rechargeable
4) V Shape metal case for easy to fit at the corner or pipe.
5) 5 Side Magnetic base
6) Audible alarming at settable angle range
7) Any angle measurement *DXL360s/c only
8) USB / Bluetooth to pc connection need adapter for DXL360 and DXL360s/c.
Specifications
Accuracy: DXL360S/C:
0 to 20°: ± (0.05°)
20 to 70°: ± (0.1°)
70 to 90°: ± (0.05°)
DXL360:
0 to 20°: ± (0.1°)
20 to 70°: ± (0.2°)
70 to 90°: ± (0.1°)
*After Calibrated
Measuring range: Single axis: 360°, Dual axis: ±40°
Resolution: DXL360S/C: 0.01°
DXL360: 0.02°
Any Angle Measurement 0.5°
Accuracy *DXL360s/c:
Gyro Rotation Speed *DXL360s/c: <50°/s
Response time: <0.4 second
absolute relativeAudio sound: 60dB @ 30cm
Zero offset drift angle per °C: 0.0058° (typical)
Operating temperature: 0 to 50°C
Storage temperature: -10 to 60°C
User Interface: Mono-color LCD with backlight
Supply Power: Rechargeable Li-Polymer 3.7V
Charger port: 5V 500mA Mini type-B USB port
Power Consumption: Standby: 10uA, Operation: 20mA.
Standby Battery Life: 4000 hours
Operating Battery Life: 40 hours
Dimensions (in mm): 70(L) x 70(W) x 23(H)
Magnetic Base: affix at 4 corner
Magnetic Force: N48
Weight: 120gram
Button Functions
Button | Function Descriptions | |
Normal Mode | MENU Mode | |
POWER | In normal operation, this button turns the device ON/OFF. | Serves as the escape key at menu mode |
ZERO | When pressed, the current reading is set to zero; subsequent measurements are relative to this reading. The LCD will show theicon to indicate the device is in zero mode. Press and hold for 3 seconds to enable or disable sound. The icon on LCD will be displaced accordingly. The buzzer alarming could be set at different accuracy level. Refer to section “Angle Alarming”. | Serves as the upward key for option selection. |
HOLD | When pressed, the current value will freeze; the unit iconflashes to indicate the reading is on hold. | Serves as the downward key at menu mode |
SET | Press and hold for 3 seconds to enter MENU mode, for set mode options. | Serves as the Set key. |
ANGLE *DXL360S/C only | Any angle measurement start button. Refer to section “Any Angle” Press and hold for 3 seconds to enter MENU mode, for set mode options. | Serves as the Set key. |
LCD Icons Representations