1 T h e P h a n t o m L a b o r a t o r y
C a t p h a n ® 500 and 600 M a n u a l
Copyright © 2015
WARRANTY
THE PHANTOM LABORATORY INCORPORATED (“Seller”) warrants that this product shall remain in good working order and free of all material defects for a period of one
(1) year following the date of purchase. If, prior to the expiration of the one (1) year warranty period, the product becomes defective, Buyer shall return the product to the
Seller at:
B y
Mail
Truck By
The Phantom Laboratory, Incorporated The Phantom Laboratory, Incorporated
2727 State Route 29 PO Box 511
Greenwich, NY12834 Salem, NY 12865-0511
Seller shall, at Seller’s sole option, repair or replace the defective product. The Warranty does not cover damage to the product resulting from accident or misuse.
IF THE PRODUCT IS NOT IN GOOD WORKING ORDER AS WARRANTED, THE
SOLE AND EXCLUSIVE REMEDY SHALL BE REPAIR OR REPLACEMENT,
AT SELLER’S OPTION. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT. THIS LIMITATION APPLIES TO DAMAGES OF ANY KIND, INCLUDING, BUT NOT LIMITED TO, DIRECT OR INDIRECT DAMAGES, LOST PROFITS, OR OTHER SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER FOR
BREACH OF CONTRACT, TORT OR OTHERWISE, OR WHETHER ARISING OUT
OF THE USE OF OR INABILITY TO USE THE PRODUCT. ALL OTHER EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANT ABILITY AND FITNESS FOR PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED.
WARNING
This product has an FH3-4 mm/min flame rating and is considered to be flammable. It is advised not to expose this product to open flame or high temperature (over 125° Celsius
or 250° Fahrenheit) heating elements.
CTP500
CTP600
12/18/15
2
3 T h e P h a n t o m L a b o r a t o r y
Catphan® Manual
Contents
Warranty 1
Introduction 5
Multi-Slice CT by David Goodenough, Ph.D. 6
Initial phantom positioning 8
Illustration of Catphan® models 9
Incremental phantom modules positioning 10
Phantom position verification 11
CTP401 and CTP404 modules 12
Patient alignment system check 13
Scan slice geometry (slice width) 14
Scan incrementation 15
Circular symmetry 16
Spatial linearity of pixel size verification 16
Spherical acrylic contrast targets 16
CT or Hounsfield Numbers by David Goodenough, Ph.D. 17
Sensitometry (CT number linearity) 18
CTP591 Bead Geometry Module 20
Measuring slice thickness with a profile made from bead image 22
Additional methods for estimating and measuring slice thickness with bead ramps 23 CTP528 High resolution module with 21 line pair per cm gauge and point source 24 Bead point source for point spread function and MTF 24
Use of automated scanner MTF programs 25
Bead point source (slice sensitivity profile) 26
21 Line pair per centimeter high resolution gauge 27centering
CTP515 Low contrast module with supra-slice and subslice contrast targets 28
CTP486 Image uniformity module 30
Installation and removal of test modules 32
Optional phantom annuli 33
Optional phantom housings 34
Dose Phantoms 35
Sample quality assurance program 36
Automated computer analysis program 36
Bibliography 37
4
5 Introduction
The Phantom Laboratory and physicist, David J. Goodenough, Ph.D., are continually developing and researching new tests and modifications for the Catphan® phantoms.
The test objects that make up the current Catphan® models embody more than a
quarter century of scientific evaluation and field experience. This manual outlines the applications of each module contained in the Catphan® 500 and 600 phantoms.
We do not make specific recommendations on the content of your quality assurance program, because each medical imaging facility has its own unique set of requirements.
A sample program is provided to give you ideas for possible program content. We
suggest a review of local governing regulations, manufacturers’ specifications and the needs of your radiologists and physicists before developing your CT quality assurance program.
The Catphan® instructional video, which illustrates the phantom setup and scanning of
the different Catphan® sections, is also available.
If you have any additional questions please contact The Phantom Laboratory at:
Phone: 800-525-1190 or 518-692-1190
Fax: 518-692-3329
email: sales@phantomlab
Additional product information is available at: www.phantomlab