Confidential. All rights reserved. No part of this document may be transmitted or reproduced without the prior written permission of a Standards Department of the Volkswagen Group.
Parties to a contract can only obtain this standard via the responsible procurement department.
© VOLKSWAGEN AG
T h e  E n g l i s h  t r a n s l a t i o n  i s  b e l i e v e d  t o  b e  a c c u r a t e . I n  c a s e  o f  d i s c r e p a n c i e s  t h e  G e r m a n  v e r s i o n  s h a l l  g o v e r n .
Q U E L L E : N O L I S
Page 2
PV 1200: 2004-10
One cycle (see Figure 1) lasts for 720 min (12 h) and comprises the following temperature and humidity profiles:
60 min heating phase to +80 °C and 80% rel. humidity,
240 min holding time at +80 °C and 80% rel. humidity,
120 min cooling phase to -40 °C, when freezing point is reached: approx. 30% rel.
humidity, the air humidity remains unregulated as of T < 0 °C
(depending on the system, humidity regulation can also
be  suspended as of T < 10 °C),
240 min holding time at -40 °C, air humidity remains uncontrolled,
60 min heating phase to +23 °C, rel. humidity is regulated to 30% as of T = 0°C Array
Figure 1 – Test cycle for PV 1200
editorially

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系QQ:729038198,我们将在24小时内删除。