IO-Link Interface Description
ThinkTop V70 IO-Link
I O D D -P D F C r e a t o r V 2.2.0.15a l f a l a v a l -00000A -20220112-I O D D 1.1, V 1.0.32C o p y r i g h t 2018, w w w .a l f a l a v a l.c o m
Vendor ID 1292 / Bytes 5-12 (hex: 05-0C)Device ID 10 / Bytes 0-10 (hex: 00-0A)Bit rate
COM2Minimum cycle time 5 ms SIO mode supported No Block parameterization Yes Data storage Yes
Supported profiles
BLOB, Binary Large Objects
Identification and Diagnosis
NOTE:
If the Vendor ID and Device ID is referenced in your PLC system, then it is ensured that - the connected Device type is correct - the IO-Link datastorage is enabled
- your application is still able to work, even your Device has been exchanged with a successor model.
For process value update rate, as well as further information concerning sensor performance, see datasheet
2 processdata
Valve position
IntegerT (16 Bit)
Current valve position. Represents the actual distance between the top of the valve actuator and the top of the valve stem.Value range [mm](0 to 1060) * 0.1
32764
(NoData) 0x7FFC
Error status
UIntegerT (6 Bit)
Short description of the current error (Troubleshooting advice is available in the Instruction manual)
Value range
(Everything is OK)
16(Sensor target missing (#16))17(Setup prerequisite issue (#17))18(Pneumatic part issue (#18))19(Seat lift sensor issue (#19))20(Position not reached (#20))21(Unexpected movement (#21))22(Seat-lift sensor missing (#22))23(Pilot valve 1 missing (#23))24(Pilot valve 2 missing (#24))25(Pilot valve 3 missing (#25))26(Interlock active (#26))27(Output short circuit (#27))28(Setup aborted (#28))29(Blocked button (#29))
30(Communication failure (#30))31
(Safety stop active (#31))
Valve state
BooleanT
Current Valve state (The valve system is OK when the signal is high)
Value range
false (Valve state NOT OK)true
(Valve state OK)
LSP
BooleanT
Lower Seat Push energised position
Value range
false (inactive)true
(active)
USL
BooleanT
Upper Seat Lift energised position
Value range
false (inactive)true
(active)
MAIN
BooleanT
Main energised Position
Value range
false (inactive)true
(active)
DE_EN
BooleanT
De-Energized
sort of link什么意思Value range
false (inactive)true
(active)
Process data displayed according device sort order.
Please note: Siemens PLCs swap the high and low byte when using byte addressing.
2 processdata
Pulse BooleanT Trigger one clean pulse on SV 1 (The pulse stroke length can be customised)
Value range false(Disable)
true(Enable)
Burst BooleanT Enable burst clean
Value range false(Disable)
true(Enable)
SV 1BooleanT Trigger solenoid valve 1 for main valve activation
Value range false(Disable)
true(Enable)
SV 2BooleanT Trigger solenoid valve 2 for upper seat lift activation
Value range false(Disable)
true(Enable)
SV 3BooleanT Trigger solenoid valve 3 for lower seat push activation
Value range false(Disable)
true(Enable)
Wink BooleanT Visual indication for locating the unit (Purple flashing as default)
Value range false(Disable)
true(Enable)
3 Parameter overview