厂商设备型号syslog摘要syslog关键字
cisco cisco7606s Adj resolve request: Failed to resolve
21.64.238.13 GigabitEthernet5/1ADJ-3-RESOLVE_REQ
cisco N7K-C7010arp [3108] Failed to get MAC address on
Vlan11 for ARP reply packet ARP-3-MAC_ERR
cisco Catalyst4506Authorization failed for client (Unknown
MAC) on Interface Gi2/25AUTHMGR-5-FAIL
cisco Catalyst4506Starting dot1x for client (4487.fc4d.db72)
on Interface Gi3/18AUTHMGR-5-START
cisco Catalyst4506Authorization succeeded for client
(0001.6c46.c315) on Interface Gi2/47AUTHMGR-5-SUCCESS
cisco Catalyst4506Failing over from dot1x for client
(Unknown MAC) on Interface Gi2/39AUTHMGR-7-FAILOVER
cisco Catalyst4506Exhausted all authentication methods for
client (Unknown MAC) on Interface Gi2/35AUTHMGR-7-NOMOREMETHODS
cisco Catalyst4506Authentication result no-response from
dot1x for client (Unknown MAC) on AUTHMGR-7-RESULT
cisco cisco7604Neighbor 30.140.1.6 reset (BGP
Notification sent)BGP-5-NBR_RESET
cisco Catalyst4507Failed to read module 3 s serial eeprom,
try reinserting module C4K_CHASSIS-3-LINECARDSEEPROMREADFAILED
cisco Catalyst4507%C4K_CHASSIS-3-MIXINPOWERDETECTED: Power
supplies in the chassis are of different C4K_CHASSIS-3-MIXINPOWERDETECTED
cisco Catalyst4507Failed to read linecard 3 muxbuffer
supervisor selection register
C4K_CHASSIS-3-
MUXBUFFERREADSUPERVISORSELECTIONFAILED
cisco Catalyst4507Poe Health Check failed on slot 4 (count
96)C4K_CHASSIS-5-POEHEALTHCHECKFAILED
cisco Catalyst4507S2w bus error while looking for changed
gbics on port Gi3/6:C4K_GBICMAN-3-S2WERROR
cisco Catalyst4506Slot 2 Port 1: Transceiver has been
inserted C4K_IOSINTF-5-TRANSCEIVERINSERTED
cisco Catalyst4507Lemans 3-4(Gi3/25-32) - management request
timed out.
C4K_LINECARDMGMTPROTOCOL-4-
INITIALTIMEOUTWARNING
cisco Catalyst4507Lemans 3-6(Gi3/41-48) - consecutive
management requests timed out.
C4K_LINECARDMGMTPROTOCOL-4-
ONGOINGTIMEOUTWARNING
cisco Catalyst4507Failed to read linecard 3 muxbuffer
supervisor selection register
C4K_SUPERVISOR-3-
MUXBUFFERREADSUPERVISORSELECTIONFAILED
cisco Catalyst4506BJT: %C4K_SWITCHINGENGINEMAN-4-
VFERPINTERRUPT: VFE RP C4K_SWITCHINGENGINEMAN-4-VFERPINTERRUPT
cisco cisco7606s module 6 device-2 temperature crossed
threshold #1( 55C). It has returned to C6KENV-SP-4-MINORTEMPALARMRECOVER
cisco cisco7304power supply 1 turned on.C7600_PWR-SP-4-PSOK
cisco cisco7304in power-redundancy mode system is
operating on both power supplies.C7600_PWR-SP-4-PSREDUNDANTBOTHSUPPLY
cisco N7K-C7010Connectivity Management processor(on
module 6) is now UP CMPPROXY-STANDBY-2-LOG_CMP_UP
cisco N7K-C7010Connectivity Management processor (on
module 6) went DOWN CMPPROXY-STANDBY-2-LOG_CMP_WENT_DOWN
cisco Catalyst4506DHCP_SNOOPING drop message because the
chaddr doesn t match source mac, message
DHCP_SNOOPING-5-
DHCP_SNOOPING_MATCH_MAC_FAIL
cisco Catalyst6509Module 3: Passed Online Diagnostics DIAG-6-DIAG_OK
cisco Catalyst4506Authentication failed for client (Unknown
MAC) on Interface Gi2/33DOT1X-5-FAIL
cisco Catalyst4506Authentication successful for client
(b4b5.2fb5.b2ba) on Interface Gi2/28DOT1X-5-SUCCESS
cisco Catalyst4507Fa4/8 suspended: LACP currently not
enabled on the remote port.EC-5-L3DONTBNDL2
cisco cisco ASR 1004Temp: Left Ext Location: F0 State: Minoractive alignment
Reading: 56 Celsius ENVIRONMENTAL-1-ALERT
cisco cisco1900Ap Warning: Intake User Temperature 43C
Exceeds 42C. Please resolve system cooling ENVMON-2-IN_OUTLET_OVERTEMP
cisco Nexus7700 C7706eigrp-1201 [4793] (default-base) IP-
EIGRP(0) 1201: Neighbor 22.20.192.10EIGRP-5-NBRCHANGE_DUAL
cisco N7K-C7010Interface Ethernet1/3 is down(Config
change)ETHPORT-5-IF_DOWN_CFG_CHANGE
cisco cisco7609Fabric ASIC 0: Fabric sync requested after
1 sync errors on serial channel 2FABRIC_INTF_ASIC-5-FABRICSYNC_REQ
cisco cisco7609Fabric ASIC 1 Channel 2: Fabric sync done.FABRIC_INTF_ASIC-DFC1-5-FABRICSYNC_DONE
cisco cisco2811Vlan21 Grp 21 active routers virtual IP
address 21.64.192.1 is different to the HSRP-4-DIFFVIP1
cisco cisco3945E No valid license available for group
datak9.IOS_LICENSE_IMAGE_APPLICATION-6-NO_LICENSE
cisco cisco ASR 1002CLEAR CRITICAL GigabitEthernet0/1/1
Physical Port Link Down IOSXE_RP_ALARM-6-INFO
cisco cisco3945E Feature securityk9 1.0 running without a
License. UDI C3900-SPE250/K9:FOC14442QCM LICENSE-1-ENFORCEMENT
cisco cisco3945E License for feature datak9 1.0 has expired
7 weeks ago. UDI C3900-LICENSE-1-EXPIRED
cisco Nexus7700 C7706Application eigrp running without
LAN_ENTERPRISE_SERVICES_PKG license LICMGR-2-LOG_LICAPP_NO_LIC
cisco cisco7609Line protocol on Interface
GigabitEthernet1/0/0 changed state to up LINEPROTO-DFC1-5-UPDOWN
cisco cisco7304No linestate vector for CH-STM1 2/0LINK-2-LINEST
cisco cisco7609Interface GigabitEthernet1/0/0 changed
state to up LINK-DFC1-3-UPDOWN
cisco Catalyst4506Detected router with duplicate router ID
21.150.7.129 in area 20734OSPF-4-DUP_RTRID_AREA
cisco cisco7609BJ: %SCP-DFC1-5-ONLINE: Module online SCP-DFC1-5-ONLINE
cisco Catalyst4507Te1/2: Voltage low alarm; Operating value:
0.00 V Threshold value: 3.00 V.SFF8472-5-THRESHOLD_VIOLATION
cisco Catalyst6509Persistent event link_down did not leave
the current state link_down : pm_port 1/14SM-SP-4-PERSIST
cisco Catalyst
3560V2-48TS
pre-standard MST interaction not
configured (GigabitEthernet0/3). Please SPANTREE-3-PRESTD_NEIGH
cisco cisco ASR 1002Signature verification failed status 8SSH-3-RSA_SIGN_FAIL cisco Catalyst6509SSH 1.99 has been enabled SSH-STBY-5-ENABLED
cisco C2960S-
UNIVERSALK9-M Switch 1 is READY STACKMGR-5-SWITCH_READY
cisco cisco7609S Same tty1 in linewatch_timers type 0SYS-3-DUP_TIMER
cisco Catalyst4507-RE redirection url write failed No space left
on device SYS-3-URLWRITEFAIL
cisco cisco3845BJ: %SYS-4-CONFIG_RESOLVE_FAILURE: System
config parse from SYS-4-CONFIG_RESOLVE_FAILURE
cisco Catalyst3550-48Configured from console by luoxj on vty0
(22.136.48.178)SYS-CLUSTER_MEMBER_2-5-CONFIG_I
cisco Catalyst6509System Controller is getting reset so
frequently SYSTEM_CONTROLLER-SP-3-EXCESSIVE_RESET
cisco C2960S-
UNIVERSALK9-M Console media-type is RJ45.USB_CONSOLE-6-MEDIA_RJ45
cisco Nexus7700 C7706USB1: online USBHSD-2-MOUNT cisco Nexus7700 C7706USB1: offline USBHSD-2-UMOUNT
syslog解释厂商处理建议
An internal software
error occurred.Copy the
message
An unexpected but recoverable error has Recommended Action: No
The client was unable to obtain authorization on Recommended Action: No
The authentication manager is starting an Recommended Action: No
Authorization was successful for the client Recommended Action: No
The authorization manager will fail over from the Recommended Action: No
All available authentication methods Recommended Action: No
The authentication result and method are displayed Recommended Action: No
The switch cannot read the serial EEPROM of the Remove and reinsert
The software detected different kinds of power Verify that both power
The active supervisor tried to read alignment Recommended Action: If
PoE health check has failed on a module. The Recommended Action: If
There was an internal communication error when Recommended Action:
An approved vendor transceiver has been Recommended Action: No
There are communication problems with the module Recommended Action:
There are communication problems with the module Recommended Action:
The active supervisor tried to read alignment Recommended Action: If
An error in the Very-fast Forwarding Engine"s Rate Recommended Action: If
The DHCP snooping feature attempted MAC address Recommended Action:
The diagnostic tests did not detect any error on Recommended Action:
Authentication was
unsuccessful.Recommended
Action: No
Authentication was successful for the Recommended Action: No
LACP is enabled on a Layer 3 interface, but Recommended Action:
One of the sensors in the system is reading an out Recommended Action:
The temperature sensor indicates that the Recommended Action:
A neighbor went up or down Recommended Action: No
FCIP interface temporarily down because Recommended Action: No
The line card has requested that the Recommended Action: No
The HSRP virtual IP address contained in the Recommended Action:
There is no valid license available on the Cisco Recommended Action: If
1. %LINK-2-LINEST: No linestate vector for Recommended Action:
OSPF has detected a router in the area that Recommended Action: The
There was a threshold violation as specified in Recommended Action:
The message means that the switch has received a Recommended Action: Use
The switch is ready. [dec] is the switch Recommended Action: No
A tty has appeared twice in a timer list in which Recommended Action:
The system failed to redirect the output to a Recommended Action:
The configuration file at the URL specified in the Recommended Action:

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系QQ:729038198,我们将在24小时内删除。