Issued Date:2014. 01. 09Test Report No. F690101/LF-CTSAYAA14-00583
KOREA ENGINEERING PLASTICS (ULSAN)578-26
Maeam-dong Nam-ku Ulsan  Korea
To:
The following merchandise was submitted and identified by the client as :SGS File No.:    AYAA14-00583Product Name :    KEPITAL1Item No./Part No.
:F20-03
Client Reference Data  :    F10-01, F10-02, F10-03H(M/LOF), F10-01 T2, F10-52, F15-33(LOF), F20-01, F20-02, F20-03(M/LOF), F20-33(LOF), F20-52(G/LOF/G LOF), F25-03(M/LOF), F25-03H(LOF),
F25-03HT(LOF), F25-63(LOF), F30-01, F30-03(M/LOF), F30-34(LOF), F30-52(G/LOF), F40-03, TX-11H(LOF), TX-11HK(LOF), TX-21(LOF), TX-31(F/LOF), MX20BT01, MX25BT01, MX30BT01, F10-52H(LOF), F10-52D 2014. 01. 062014. 01. 09
to 2014. 01. 07
Received Date  :
Test Period                  :Test Results :
For further details, please refer to following page(s)Test Performed
:By the applicant’s request, item No.s/part No.s & client reference information are stated/added on
report.
Timothy Jeon  Jinhee Kim  Cindy Park
Jerry Jung/ Testing Person
Jeff Jang / Chemical Lab Mgr
SGS Korea Co., Ltd.
This document is issued by the Company subject to  its General Conditions of Service printed overleaf, available on request or accessible at www.sgs/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
Page 2 of 4
Issued Date:2014. 01. 09Test Report No. F690101/LF-CTSAYAA14-00583
Sample No. :AYAA14-00583.001KEPITAL1Sample Description :Item No./Part No.:F20-03N/A
Materials    :Heavy Metals
Results
MDL Test Method Unit Test Items
0.5With reference to IEC 62321:2013, ICP Cadmium (Cd)/kg 5With reference to IEC 62321:2013, ICP Lead (Pb)/kg 2With reference to IEC 62321:2013, ICP Mercury (Hg)
/kg 1
With reference to IEC 62321:2008, UV-VIS
Hexavalent Chromium (Cr VI)
N.D.
mg/kg
NOTE:
(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm
(3) MDL = Method Detection Limit (4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable (6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction        solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to  its General Conditions of Service printed overleaf, available on request or accessible at www.sgs/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
Test Report No. F690101/LF-CTSAYAA14-00583
Page 3 of 4
Issued Date:2014. 01. 09
Picture of Sample as Received:
NOTE:
(1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overlea
f, available on request or accessible at www.sgs/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
Page 4 of 4
Issued Date:2014. 01. 09Test Report No. F690101/LF-CTSAYAA14-00583
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr 6+/PBBs&PBDEs Testing
Sample Measurement
DATA
GC/MS
Solvent Extraction  of the Sample
Screen Analysis
Concentration/Dilution of Extraction Solution
Filtration
Cd/Pb/Hg
PBBs/PBDEs
Mechanic_Sample
reference groupSample Measurement
Acid Digestion with Microwave/Hotplate
Filtration
Residue
Total Digestion
ICP-AES/AAS/MS
DATA
Mechanic_Sample
Confirm with UV-Vis
Cr
Sample Measurement
Adding Extraction Solution
Metallic Material
UV-Vis
DATA
Mechanic_Sample 6+
Filtration and pH Adjustment
Adding 1,5-Diphenylcarbazide
for Color Development
Heating to 90~95°C      for Extraction
Nonmetallic Material
Adding 1,5-Diphenylcarbazide for Color Development
Mechanic_Sample
Sample Measurement
Spot Test / Boiling Water Extraction DATA
Cr
6+
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg.    Section Chief  :  Gilsae Yi
*** End ***
NOTE:
(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm
(3) MDL = Method Detection Limit (4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable (6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction        soluti
on is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to  its General Conditions of Service printed overleaf, available on request or accessible at www.sgs/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if