Auto CO2 Lab Control Unit
Models – EA-34000
1-877-559-0159 Toll Free                                                    Euthanex Corp. / E-Z Systems 1-610-882-3801 Fax                                                                                      P.O. Box systemsinc                                                                            Palmer, PA 18043
Table of Contents
Disclaimer and Lab Control Unit
Overview (3)
Safety Instructions (4)
System Set-Up (5)
Operating the System (8)
Changing System Presets (10)
Flow Rate & Preset Times (12)
EMC / EMI.
This equipment has been tested and found to
comply with the limits for a Class A Equipment,
pursuant to part 15 of the FCC rules.
IEC 61326-1:2005 / EZ 61326-1:2006
For the customers in Canada:
This Class A Equipment complies with
Canadian ICES-003:2012.
Cet appareil numérique de la classe A est
conforme à la norme NMB-003:2012 du Canada.
THIS MANUAL MUST BE READ BEFORE SETTING UP AND OPERATING THE SMARTBOX AUTO CO2 SYSTEM. The user should be thoroughly familiar with the contents of this manual prior to using the system with animals.  Only technicians that are properly certified should operate the system.
The user/owner of this equipment shall have the sole responsibility for any damage or injury resulting from operation that is not in accordance with the authorized instructions. This includes, but is not limited to, operating the equipment outside of recommended safety levels, variation from specified operating instructions, and not following standard laboratory safety procedures when working with anesthetic agents and volatile compressed gases.
The system and its components must only be modified or repaired by Euthanex authorized service technicians. Improper modification or repair may result in danger to personnel, harm or death to animal, and/or equipment damage. The user/owner of this equipment shall have the sole responsibilit
y for any damage or injury resulting from improper maintenance and repair that is not done by authorized maintenance and repair personnel.
Parts that have failed, in whole or in part, exhibit excessive wear, are contaminated or are otherwise at the end of their useful life, should not be used and should be replaced with parts supplied by Euthanex Corporation. Tampering with the main control unit by unauthorized personnel automatically voids all warranties and specifications. The manufacturer assumes no responsibility for any malfunction or failure of the unit if tampering is suspected.
Overview:
The Lab Control Unit utilizes a programmable logic controller (PLC) that delivers a set volume of CO2 into an individual animal cage through the Euthanex Lid.  The controller unit operates at a fixed flow rate that is set at your external CO2 source.  Gas flows from the external source into the Lab Control Unit.  A solenoid valve opens to output gas to the Euthanex Lid.  After the euthanasia cycle is completed, the Lab Control Unit automatically shuts the gas off.
The EA-34000 model treats 4 cages or chambers.
The Lab Control Unit comes with one preset gas delivery timing.  The EA-34000 offers 4 programmable timing.  It is highly recommended that only designated, trained personnel make adjustments to the timings, to ensure safe and effective settings.
Please refer to the “Flow Rate & Preset Times” section to derive the AVMA recommended flow rate.
The lightning flash with an arrowhead
symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
1.Read these instructions.
2.Keep these instructions.
3.Heed all warnings.
4.Follow all instructions.
5.Do not use this unit near water.
6.Do not clean by spraying liquid directly onto
unit.
7.Do not block any ventilation openings.
Install in accordance with the manufacturer's
instructions.
8.Do not install near any heat sources such
as radiators, heat registers, stoves, or other
unit that produce heat.
9.Do not defeat the safety purpose of the
polarized or grounding-type plug. A
polarized plug has two blades with one
wider than the other. A grounding type plug
has two blades and a third grounding
prong. The wide blade or the third prong
are provided for your safety. If the provided
plug does not fit into your outlet, consult an
electrician for replacement of the obsolete
outlet.
10.Protect the power cord from being walked
on or pinched particularly at plugs,
convenience receptacles, and the point
where they exit from the unit.
11.Unplug this unit during lightning
storms or when unused for long periods of
time.
12.Refer all servicing to qualified service
personnel. Servicing is required when the
unit has been damaged in any way,
such as power-supply cord or plug is
damaged, liquid has been spilled or objects
have fallen into the unit, the
unit has been exposed to rain or
moisture, does not operate normally, or has
been dropped.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Warning!
∙To reduce the risk of fire or electric shock, do not expose this unit to rain or
moisture.
∙Use line cord supplied with the product.
∙Be advised that different operating voltages require the use of different types of line
cord and attachment plugs.  The unit was
shipped with the requested plug.  If the
installation requirements change please
contact us for the correct plug.
move off∙This equipment should be installed near the socket outlet and disconnection of the device
should be easily accessible.
∙Do not install in a confined space.
∙Do not open the unit - risk of electric shock inside.
Caution:
You are cautioned that any change or
modifications not expressly approved in this
manual could void your authority to operate
this equipment.
Service
∙There are no user-serviceable parts inside.
∙All service must be performed by qualified personnel.
Voltage
100-240 v ac 50-60hz 1 amp Max (auto
select)
Pressure 75 psi max to inlet
Temp
0 to 40°C <> 10 to 85% RH (no
condensation)
System Set-Up:
1.  Four mounting brackets are utilized to secure the controller unit to the wall.  These are on the controller when shipped.
2. Using a Phillips head screwdriver, loosen the screws and move the mount tabs outward as pictured below. Tighten the screws once appropriate position is achieved.