Notes:
(1) Reverse recovery test conditions: I F =0.5A, I R =1.0A, I rr =0.25A (2) Measured at 1.0MHz and applied reverse voltage of 4.0 volts (3) 8.0mm 2
(0.013mm thick) land areas
Symbols GN3A GN3B GN3D
GN3G GN3J GN3K
GN3M Units
Maximum repetitive peak reverse voltage
profile中文V RRM 50100200
400600
8001000Volts Maximum RMS voltage V RMS 3570140280420560700Volts Maximum DC blocking voltage
V DC
50
100
200
400
600
800
1000
Volts
Maximum average forward rectified current at T L =75
at rated DC blocking voltage T A =125A
Typical reverse recovery time (Note 1)
T rr
2.5
F
Maximum thermal resistance (Note 3)
R
JA
13.047.0
Features
Mechanical Data
GN3A THRU GN3M
SURFACE MOUNT GLASS PASSIVATED JUNCTION RECTIFIER
Reverse Voltage - 50 to 1000 Volts Forward Current - 3.0 Amperes
/10 seconds at terminals
method 2026
ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.For capacitive load, derate current by 20%.
RATINGS AND CHARACTERISTIC CURVES
2
版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系QQ:729038198,我们将在24小时内删除。
发表评论