Highly Accelerated Temperature and Humidity Stress Test (HAST)
JESD22-A110C
(Revision of JESD22A110-B, January 1999)
JANUARY 2009
JEDEC SOLID STATE TECHNOLOGY ASSOCIATION
NOTICE
JEDEC standards and publications contain material that has been prepared, reviewed, and approved through the JEDEC Board of Directors level and subsequently reviewed and approved
by the JEDEC legal counsel.
JEDEC standards and publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improve
ment of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for use by those other than JEDEC members, whether the standard is to
be used either domestically or internationally.
JEDEC standards and publications are adopted without regard to whether or not their adoption may involve patents or articles, materials, or processes. By such action JEDEC does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting
the JEDEC standards or publications.
The information included in JEDEC standards and publications represents a sound approach to product specification and application, principally from the solid state device manufacturer viewpoint. Within the JEDEC organization there are procedures whereby a JEDEC standard or publication may be further processed and ultimately become an ANSI standard.
No claims to be in conformance with this standard may be made unless all requirements stated in
the standard are met.
Inquiries, comments, and suggestions relative to the content of this JEDEC standard or publication should be addressed to JEDEC at the address below, or call (703) 907-7559 or
Published by
©JEDEC Solid State Technology Association 2009
3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107
This document may be downloaded free of charge; however JEDEC retains the
copyright on this material.  By downloading this file the individual agrees not to
charge for or resell the resulting material.
PRICE: Please refer to the current
Catalog of JEDEC Engineering Standards and Publications online at
/Catalog/catalog.cfm
Printed in the U.S.A.
All rights reserved
PLEASE!
DON’T VIOLATE
THE
LAW!
editordoesnotcontainamaintypeThis document is copyrighted by JEDEC and may not be
reproduced without permission.
Organizations may obtain permission to reproduce a limited number of copies  through entering into a license agreement.  For information, contact:
JEDEC Solid State Technology Association
3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107
or call  (703) 907-7559
JEDEC Standard No. 22-A110C
Page 1
Test Method A110C
(Revision of A110-B) TEST METHOD A110C
HIGHLY-ACCELERATED TEMPERATURE
AND HUMIDITY STRESS TEST (HAST)
(From JEDEC Board Ballot JCB-08-92, formulated under the cognizance of JC-14.1 Committee on Reliability Test Methods for Packaged Devices.)
1 Scope
The Highly-Accelerated Temperature and Humidity Stress Test is performed for the purpose of evaluating the reliability of non-hermetic packaged solid-state devices in humid environments. It employs severe conditions of temperature, humidity, and bias which accelerate the penetration of moisture through the external protective material (encapsulant or seal) or along the interface between the external protective material and the metallic conductors which pass through it. The stress usually activates the same failure mechanisms as the “85/85” Steady-State Humidity Life Test (JEDEC Standard No. 22-A101).
2 Apparatus
The test requires a pressure chamber capable of maintaining a specified temperature and relative humidity continuously, while providing electrical connections to the devices under test in a specified biasing configuration.
2.1 Controlled conditions
The chamber must be capable of providing controlled conditions of pressure, temperature and relative humidity during ramp-up to, and ramp-down from the specified test conditions. Calibration records shall verify that the equipment avoids condensation on devices under test (DUTs) hotter than 50 ºC during ramp-up and ramp-down for conditions of maximum thermal mass loading and minimum (zero) DUT power dissipation. Calibration records shall verify that, for steady state conditions and maximum thermal mass loading, test conditions are maintained within the tolerances specified in 3.1.
2.2 Temperature profile
A permanent record of the temperature profile for each test cycle is recommended, so that the validity of the stress can be verified.
2.3 Devices under stress
Devices under stress must be physically located to minimize temperature gradients. Devices under stress shall be no closer than 3 cm from internal chamber surfaces, and must not be subjected to direct radiant heat from heaters. Boards on which devices are mounted should be oriented to minimize interference with vapor circulation.