Electrical Specifications – AC Characteristics and Operating Conditions AC Characteristics: Command, Data, and Address Input (3.3V)
Notes: 1.Operating mode timings meet ONFI timing mode 5 parameters.
2.Timing for t ADL begins in the address cycle, on the final rising edge of WE#, and ends
with the first rising edge of WE# for data input.
AC Characteristics: Command, Data, and Address Input (1.8V) Note 1
Notes: 1.Operating mode timings meet ONFI timing mode 4 parameters.
2.Timing for t ADL begins in the address cycle on the final rising edge of WE#, and ends
with the first rising edge of WE# for data input.
4Gb, 8Gb, 16Gb: x8, x16 NAND Flash Memory Electrical Specifications – AC Characteristics and Operating Conditions
Electrical Specifications – DC Characteristics and Operating Conditions DC Characteristics and Operating Conditions (3.3V)
Notes: 1.Measurement is taken with 1ms averaging intervals and begins after V CC reaches
V CC(MIN).
2.I OL (R/B#) may need to be relaxed if R/B pull-down strength is not set to full.
3.V OH and V OL may need to be relaxed if I/O drive strength is not set to full.
DC Characteristics and Operating Conditions (1.8V)
Notes: 1.Typical and maximum values are for single-plane operation only. If device supports dual-
plane operation, values are 20mA (TYP) and 40mA (MAX).
2.Values are for single-die operations. Values could be higher for interleaved-die opera-
tions.
3.Measurement is taken with 1ms averaging intervals and begins after V CC reaches
V CC(MIN).
4.Test conditions for V OH and V OL.字符串长度和占用内存字节
5.DC characteristics may need to be relaxed if R/B# pull-down strength is not set to full.